maxi m u m ratings t ypical ope r ati o n c lass of t ype of s ervice p late p late p late s creen p late drive output operation voltage c urrent voltage voltage c urrent p ower p ower (volts) ( a mps) (volts) (volts) ( a mps) (watts) (kilowatts) c rf a mplifer 7,000 3.5 5,700 --- 2.5 600 10.0 the 3CX6000A7/yu-148 high-mu, forced air cooled power triode provides relatively high power output as an amplifer, oscillator, or modu - lator at low plate voltages. the tube has a low inductance cylindrical flament stem structure which readily becomes part of a linear flament tank circuit for vhf operation. the grid provides shielding between the input and output circuits for grounded grid applications and conveniently terminates in a ring between the plate and fla - ment terminals. 3 cx 6000 a 7 / yu -148 cpi | 4 c w50,000j for information on this and other cpi mpp products, visit our website at: www.cpii.com , or contact: cpi microwave products division, eimac operation, 607 hansen way, palo alto, ca 94303 t e l e p h o n e : 1(800) 414-8823. f a x : (650) 592-9988 | e m a i l : powergrid@cpii.com the values listed above represent specifed limits for the product and are subject to change. the data should be used for basic information only. formal, controlled specifcations may be obtained from cpi for use in equipment design. c ha r acte r istics plate dissipation (max.) 6,000 watts screen dissipation (max.) n/a grid dissipation (max.) 225 watts frequency for max. rating (cw) 110 mhz amplifcation factor 200 filament/cathode thoriated tungsten voltage 7.0 volts current 78.0 amps capacitance grounded cathode input 42.0 pf output 0.28 pf feedthrough 24 pf capacitance n/a input n/a output n/a feedthrough n/a cooling forced air base special, coaxial air socket n/a air chimney n/a boiler n/a length 9.00 in; 22.86 cm diameter 6.125 in; 15.56 cm weight 9.1 lb; 4.1 kg cpi | 3 cx 6000 a 7 / yu -148
|